EGAD00001003136
We carried out whole-genome oxidative bisulfite sequencing (WGoxBS) in the placentas of two healthy female and two healthy male pregnancies generating an average genome depth of coverage of 25x. The sex-specific differential methylation pattern observed in this region was validated in additional 8 healthy placentas (including 2 from the WGoxBS) using SureSelect in-solution target capture. For WGoxBS, placental genomic DNA (4 µg) from 4 healthy pregnancies was processed to achieve 10 kb fragments with the g-Tube (Covaris), according to the manufacturer's instructions. To increase the number of uniquely sequenced reads, two independent libraries were generated for each individual. Multiplexed sequencing was carried out on the Illumina MiSeq, HiSeq 2000, and HiSeq 2500 instruments with 2x100, 2x50 and 2x125 cycles using MiSeq Reagent Kit v3, HiSeq SBS Kit v3 and HiSeq SBS Kit v4, respectively. For SureSelect in-solution capture, placental genomic DNA (3.5 µg) from 8 healthy pregnancies (including 2 from the WGoxBS) was fragmented by the Covaris S220 system according to the SureSelect Methyl-Seq target enrichment protocol (Agilent). All 8 libraries were pooled and sequenced on the Illumina HiSeq 2500 instrument with 2 × 125 cycles using HiSeq SBS Kit v4 and a single lane of the Illumina HiSeq 4000 instrument with 2 × 150 cycles using HiSeq 3000/4000 SBS Kit following Illumina's guidelines (Illumina Application Note: Epigenetics February 2016).
Illumina HiSeq 2500
10
EGAD00001003457
Placental biopsies (n = 64 female placentas, n = 67 male placentas) were selected from healthy pregnancies from the POPs cohort. These patients had no evidence of hypertension at booking and during pregnancy, did not experience pre-eclampsia, Hemolysis, Elevated Liver enzymes, and Low Platelets (HELLP) syndrome, gestational diabetes, or diabetes mellitus type I or type II and other obstetric complications. They delivered live babies with a birth weight percentile in the normal range (20-80th percentile), with no evidence of slowing in fetal growth trajectory. Chorionic villi from the corresponding placentas (free from decidua, visible infarction, calcification, hematoma, or damage) were collected and processed within 30 minutes of separation from the uterus. After repeated washes in chilled phosphate buffered saline, the samples were placed in RNA later (Applied Biosystems) and stored at -80°C. Total placental RNA was extracted using mirVana Isolation Kit (Ambion). For each placenta, approximately 5 mg of tissue were homogenized in the Lysis/Binding solution for 20 sec at 6 m/s using a bead beater (FastPrep24) and Lysing Matrix D Tubes (MP Biomedicals). The samples were then spun at 13,000 rpm for 5 min at 4°C and the supernatants recovered. Afterwards, the manufacturer's instructions were followed. Immediately after the RNA extraction, placental RNA samples were DNase-treated using DNA-free DNA Removal Kit (Ambion), aliquoted, and stored in -80°C. Quantity and quality of the RNA samples were assessed using the Agilent 2100 Bioanalyzer, the Agilent RNA 6000 Nano Kit (Agilent Technologies), and Qubit fluorometer.
Libraries were prepared starting with 300-500 ng of good quality total RNA (RIN ≥7.5) using the TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Human/Mouse/Rat (Illumina), according to the manufacturer's instructions. The kit contains 96 uniquely indexed adapter combinations in order to allow pooling of multiple samples prior to sequencing. After determining their size (with the Agilent 2100 Bioanalyzer and the Agilent High Sensitivity DNA Kit by Agilent Technologies) and concentration (by qPCR with the KAPA Illumina ABI Prism Library Quantification Kit, Kapa Biosystems), libraries have been pooled and sequenced (single-end, 125 bp) using a Single End V4 Cluster Kit and an Illumina HiSeq2500 or HiSeq4000 instrument.
Illumina HiSeq 4000
147
EGAD00001003462
Placental biopsies (n = 64 female placentas, n = 67 male placentas) were selected from healthy pregnancies from the POPs cohort. A quality control process was also applied for the RNA-Seq datasets: reads were trimmed with Trim Galore!, which uses cutadapt internally and were mapped to the same version of human genome reference (hg19). TopHat2, a splice-aware mapper built on top of Bowtie2 short-read aligner, was used in the mapping process in which so-called two-pass (or two-scan) alignment protocol was applied to rescue unmapped reads from the initial mapping step. In the second mapping, previously unmapped reads were re-aligned to the exon-intron junctions detected in the first-mapping by TopHat2 and were combined across all 131 placenta samples. The initial and second mapped reads were merged by samtools
Illumina HiSeq 4000
147
EGAD00001003507
All the samples were obtained from the Pregnancy Outcome Prediction–a prospective cohort study of nulliparous women attending the Rosie Hospital, Cambridge (UK) for their dating ultrasound scan between January 14, 2008, and July 31, 2012. Ethical approval for the study was given by the Cambridgeshire 2 Research Ethics Committee (reference number 07/H0308/163) and all participants provided written informed consent. Cases of preeclampsia (PET) were defined on the basis of the 2013 ACOG criteria and cases of small for gestational age (SGA)infants were confined to severe SGA, i.e. a customized birth weight <5th percentile.
Chorionic villi from the corresponding placentas (free from decidua, visible infarction, calcification, hematoma, or damage) were collected and processed within 30 minutes of separation from the uterus. After repeated washes in chilled phosphate buffered saline, the samples were placed in RNA later (Applied Biosystems) and stored at -80°C. Total placental RNA was extracted using mirVana Isolation Kit (Ambion). For each placenta, approximately 5 mg of tissue were homogenized in the Lysis/Binding solution for 20 sec at 6 m/s using a bead beater (FastPrep24) and Lysing Matrix D Tubes (MP Biomedicals). The samples were then spun at 13,000 rpm for 5 min at 4°C and the supernatants recovered. Afterwards, the manufacturer's instructions were followed. Immediately after the RNA extraction, placental RNA samples were DNase-treated using DNA-free DNA Removal Kit (Ambion), aliquoted, and stored in -80°C. Quantity and quality of the RNA samples were assessed using the Agilent 2100 Bioanalyzer, the Agilent RNA 6000 Nano Kit (Agilent Technologies), and Qubit fluorometer.
Libraries were prepared starting with 300-500 ng of good quality total RNA (RIN ≥7.5) using the TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Human/Mouse/Rat (Illumina), according to the manufacturer's instructions. The kit contains 96 uniquely indexed adapter combinations in order to allow pooling of multiple samples prior to sequencing. After determining their size (with the Agilent 2100 Bioanalyzer and the Agilent High Sensitivity DNA Kit by Agilent Technologies) and concentration (by qPCR with the KAPA Illumina ABI Prism Library Quantification Kit, Kapa Biosystems), libraries have been pooled and sequenced (single-end, 125 bp) using a Single End V4 Cluster Kit and an Illumina HiSeq2500 or HiSeq4000 instrument.
Illumina HiSeq 4000
52
EGAD00001003508
All the samples were obtained from the Pregnancy Outcome Prediction–a prospective cohort study of nulliparous women attending the Rosie Hospital, Cambridge (UK) for their dating ultrasound scan between January 14, 2008, and July 31, 2012. Ethical approval for the study was given by the Cambridgeshire 2 Research Ethics Committee (reference number 07/H0308/163) and all participants provided written informed consent. Cases of preeclampsia (PET) were defined on the basis of the 2013 ACOG criteria and cases of small for gestational age (SGA)infants were confined to severe SGA, i.e. a customized birth weight <5th percentile.
Chorionic villi from the corresponding placentas (free from decidua, visible infarction, calcification, hematoma, or damage) were collected and processed within 30 minutes of separation from the uterus. After repeated washes in chilled phosphate buffered saline, the samples were placed in RNA later (Applied Biosystems) and stored at -80°C. Total placental RNA was extracted using mirVana Isolation Kit (Ambion). For each placenta, approximately 5 mg of tissue were homogenized in the Lysis/Binding solution for 20 sec at 6 m/s using a bead beater (FastPrep24) and Lysing Matrix D Tubes (MP Biomedicals). The samples were then spun at 13,000 rpm for 5 min at 4°C and the supernatants recovered. Afterwards, the manufacturer's instructions were followed. Immediately after the RNA extraction, placental RNA samples were DNase-treated using DNA-free DNA Removal Kit (Ambion), aliquoted, and stored in -80°C. Quantity and quality of the RNA samples were assessed using the Agilent 2100 Bioanalyzer, the Agilent RNA 6000 Nano Kit (Agilent Technologies), and Qubit fluorometer.
Libraries were prepared starting with 300-500 ng of good quality total RNA (RIN ≥7.5) using the TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Human/Mouse/Rat (Illumina), according to the manufacturer's instructions. The kit contains 96 uniquely indexed adapter combinations in order to allow pooling of multiple samples prior to sequencing. After determining their size (with the Agilent 2100 Bioanalyzer and the Agilent High Sensitivity DNA Kit by Agilent Technologies) and concentration (by qPCR with the KAPA Illumina ABI Prism Library Quantification Kit, Kapa Biosystems), libraries have been pooled and sequenced (single-end, 125 bp) using a Single End V4 Cluster Kit and an Illumina HiSeq2500 or HiSeq4000 instrument.
Illumina HiSeq 4000
91
EGAD00001004197
We spiked a small number of placental tissue samples with different combinations of Candida albicans, Plasmodium falciparum, Toxoplasma gondii, Human Cytolomega virus and Salmonella bongori (various combination of the equivalents of 1, 10, 100, 1000 and 10000 genome copies). A DNA isolation was performed on these spiked samples and the resulting DNA was subsequently sequenced by MiSeq (18S). These same samples were also analysed by X Ten to allow for a sensitivity comparison of the two methods of the eukaryotic spiked signals (Candida albicans, Plasmodium falciparum and Toxoplasma gondii). In addition, non-spiked placental samples from 50 cases of Fetal Growth Restriction (FGR) (+ matched healthy controls) and 49 cases of Preeclampsia (+ matched healthy controls) and 100 preterm cases were analyzed for their non-human eukaryotic content.
HiSeq X Ten
7
EGAD00001004198
Metagenomics data of 80 placental tissue samples analyzed by X Ten for their possible microbial content. These 80 samples from pre-labor C-section deliveries, representing Cohort 1, were spiked with 1100 CFU Salmonella bongori. These same samples were also analyzed by 16S amplicon sequencing (search for ERP109246 in ENA).
HiSeq X Ten
80
EGAD00001004592
Raw data used in the analysis of chromosomally integrated HHV6 genomes in parent-infant pairs, generated by means of full viral genome sequencing by SureSelect target enrichment, in the context of a larger study investigating the relationship between HHV6 and adverse pregnancy outcome.
Illumina MiSeq
24
EGAD00001004860
Placental biopsies were collected within 30 minutes of birth and flash frozen in RNAlater(ThermoFisher). For each biopsy,total placental RNA was extracted from approximately 5 mg of tissue using the “mirVana miRNA Isolation Kit” (Ambion) followed by DNase treatment (“DNA-free DNA Removal Kit”, Ambion). RNA quality was assessed with the Agilent Bioanalyzer and all the samples with RIN values ≥ 7.0 were used in the downstream experiments. Total RNA-libraries were prepared from 300-500ng of total placental RNA with the “TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Human/Mouse/Rat”(Illumina). Small RNA-libraries were prepared from 150ng of total placental RNA with the “NEBNext Multiplex Small RNA Library Prep Kit for Illumina”(New England Biolabs)and concentrated using the “QIAquick PCR purification kit”(Qiagen). Paired libraries were combined and size selected using the Pippin Prep and 3% Agarose Gel Cassette with marker F (Sage Science),pooled and sequenced (single-end, 50bp) using a Single End V4 cluster kit and HiSeq4000 instrument.
Illumina HiSeq 4000
288
EGAD00001006304
FASTQ files of the polyA+ (oligo-dT) RNA-Seq dataset from the POPS SGA (Small for Gestational Age) samples and their matched controls. The POP study placental biopsies were collected within 30 minutes of birth and flash frozen in RNAlater (ThermoFisher). For each biopsy, total placental RNA was extracted from approximately 5 mg of tissue using the “mirVana miRNA Isolation Kit” (Ambion) followed by DNase treatment (“DNA-free DNA Removal Kit”, Ambion). RNA quality was assessed with the Agilent Bioanalyzer and all the samples with RIN values ≥ 7.0 were used in the downstream experiments. RNA-libraries were prepared from 1g of total placental RNA with the TruSeq Stranded mRNA Library Prep Kit (Illumina) which captures polyA-tailed transcripts by oligo-dT beads, then pooled and sequenced (single-end, 50bp) using a Single End V4 cluster kit and Illumina HiSeq2500
Illumina HiSeq 2500
59