Login
Register
Need Help?
ABOUT
ABOUT THE EGA
EGA
Privacy Notice
Security
Team
STATISTICS
Bibliography
Growth
Community
Archive
Distribution
Catalog
PROJECTS AND FUNDERS
Projects
Funders
GA4GH
Federated EGA
Beacon
DISCOVERY
CATALOGUE
Studies
Datasets
DACs
Synthetic Data
METADATA
Search Box
Public Metadata API
SUBMISSION
DATA
File preparation
Uploading files
METADATA
EGA Schema
Sequencing & Phenotype
Submitter Portal
Submitter Portal API
Array
Programmatic Submission XML
ACCESS
DATA ACCESS COMMITTEE
What is a DAC?
Best Practices
DAC Portal
Data Use Conditions
REQUEST DATA
How to request data?
Quality Control Reports
DOWNLOAD
Metadata
Files
PyEGA3
Live Outbox
Visualisation
FUSE Client
EGA QuickView
Tips on how to search
DACs
EGAC00001001588
Nicola Murray Centre for Ovarian Cancer Research Data Access Committee
Request Access
This DAC controls 5 datasets
Dataset ID
Description
Technology
Samples
EGAD00001006389
Whole Exome sequencing data of tumour samples for 112 patients with endometrioid ovarian carcinoma in FASTQ format. Data was derived as summarized below: Library Preparation: Libraries were prepared from each DNA sample using the Illumina TruSeq Exome Library Prep kit (#FC-150-1002) according to the provided protocol using modifications for working with FFPE sourced material. Libraries were quantified using the Qubit 2.0 Fluorometer and the Qubit DNA HS assay (#Q32854) and the size distribution of fragments was assessed using the Agilent Bioanalyser with the DNA HS Kit (#5067-4626). Library QC: Exome-captured sequencing library pools were quantified using the Qubit 2.0 Fluorometer and the Qubit DNA HS assay (#Q32854) and the size distribution of fragments was assessed using the Agilent Bioanalyser with the DNA HS Kit (#5067-4626). Fragment size and quantity measurements were used to calculate molarity for each library pool. Sequencing: Sequencing was performed using the NextSeq 500/550 High-Output v2 (150 cycle) Kit (# FC-404-2002) on the NextSeq 550 platform (Illumina Inc, #SY-415-1002).
NextSeq 550
112
EGAD00001009048
Somatic RNA for 40 samples matched to the WGS was extracted using the Qiagen Qiasymphony RNA protcol (cat no 931636). The tissue was initially homogenised using a Qiagen Bioruptor, followed by the manufacturers recommended protocol (including DNase digestion). The resulting RNA the underwent quality control as follows: firstly, A260 and A280nm were measured on a Denovix DS-11 Fx to qualitatively illustrate A260/280nm and A260/230nm ratios as measures of RNA purity. A260/280 had to be 2.0 and A260/230 had to be 2.0-2.2. Then RNA was quantified using LifeTechnologies Qubit RNA BR kit (cat no Q10210). RNAseq was carried out by the Edinburgh Clinical Research Facility on an Illumina NExtSeq500. Total RNA samples were assessed on the Agilent Bioanalyser (Agilent Technologies, #G2939AA) with the RNA 6000 Nano Kit (#5067-1512) for quality and integrity of total RNA, and then quantified using the Qubit 2.0 Fluorometer (Thermo Fisher Scientific Inc, #Q32866) and the Qubit RNA HS assay kit (#Q32855). Libraries were prepared from total-RNA sample using the NEBNext Ultra 2 Directional RNA library prep kit for Illumina (#E7760S) with the NEBNext rRNA Depletion kit (#E6310) according to the provided protocol. 400ng of totalRNA was then added to the ribosomal RNA (rRNA) depletion reaction using the NEBNext rRNA depletion kit (Human/mouse/rat) (#E6310). This step uses specific probes that bind to the rRNA in order to cleave it. rRNA-depleted RNA was then DNase treated and purified using Agencourt RNAClean XP beads (Beckman Coulter Inc, #66514). RNA was then fragmented using random primers before undergoing first strand and second strand synthesis to create cDNA. cDNA was end repaired before ligation of sequencing adapters, and libraries were enriched by PCR using the NEBNext Multiplex oligos for Illumina set 1 and 2 (#E7500). Final libraries had an average peak size of 271bp. Libraries were quantified by fluorometry using the Qubit dsDNA HS assay and assessed for quality and fragment size using the Agilent Bioanalyser with the DNA HS Kit (#5067-4626). Sequencing was performed using the NextSeq 500/550 High-Output v2 (150 cycle) Kit (# FC- 404-2002) on the NextSeq 550 platform (Illumina Inc, #SY-415-1002). Libraries were combined in an equimolar pool based on the library quantification results and run across 5 High-Output Flow Cell v2.5.
NextSeq 550
-
EGAD00001009049
FASTQ reads for 81 matched tumour-normal WGS pairs for high grade serous ovarian cancer patients. Scottish HGSOC samples were collected via local Bioresource facilities at Edinburgh, Glasgow, Dundee and Aberdeen and stored in liquid Nitrogen until required. HGSOC patients were determined from pathology records and were included in the study where there was matched tumour and whole blood samples. Tumour samples were divided into two for DNA and RNA extraction and slivers of tissue were taken, fixed in formalin and embedded in paraffin wax (FFPE). Samples were only included if they were confirmed as HGSOC and there was greater than 40% tumour cellularity throughout the tumour, determined using H&E staining of the FFPE sections and pathology review. Somatic DNA was extracted from the tumour and germline DNA was extracted from whole blood. Somatic DNA was extracted using the Qiagen DNeasy Blood and tissue kit (cat no 69504). The tissue was initially homogenised using a Qiagen Bioruptor, followed by the manufacturers recommended protocol (including RNase digestion step). Germline DNA was extracted from 1-3ml whole blood using the Qiagen FlexiGene kit (cat no 51206) following the manufacturers recommended protocol. The resulting DNA underwent quality control as follows: firstly, A260 and A280nm were measured on a Denovix DS-11 Fx to qualitatively illustrate A260/280nm and A260/230nm ratios as surrogate measures of DNA purity. A260/280 had to be 1.8 or greater and A260/230 had to be 2.0 or greater. Then, DNA was quantified using LifeTechnologies Qubit dsDNA BR kit (cat no Q32850) and we required a minimum of 50ul at 25ng/ul for WGS. Thirdly, DNA was diluted to 25ng/ul and a representative sample was loaded onto a 0.8% TAE gel, ran at 100v for 60mins and then imaged using a BioRad ChemiDoc imaging system to visualise the DNA quality.
HiSeq X Ten
Illumina NovaSeq 6000
-
EGAD00001010135
FASTQ reads for 34 matched tumour-normal WGS pairs for high grade serous ovarian cancer patients. Scottish HGSOC samples were collected via local Bioresource facilities at Edinburgh, Glasgow, Dundee and Aberdeen and stored in liquid Nitrogen until required. HGSOC patients were determined from pathology records and were included in the study where there was matched tumour and whole blood samples. Tumour samples were divided into two for DNA and RNA extraction and slivers of tissue were taken, fixed in formalin and embedded in paraffin wax (FFPE). Samples were only included if they were confirmed as HGSOC and there was greater than 40% tumour cellularity throughout the tumour, determined using H&sE staining of the FFPE sections and pathology review. Somatic DNA was extracted from the tumour and germline DNA was extracted from whole blood. Somatic DNA was extracted using the Qiagen DNeasy Blood and tissue kit (cat no 69504). The tissue was initially homogenised using a Qiagen Bioruptor, followed by the manufacturers recommended protocol (including RNase digestion step). Germline DNA was extracted from 1-3ml whole blood using the Qiagen FlexiGene kit (cat no 51206) following the manufacturers recommended protocol. The resulting DNA underwent quality control as follows: firstly, A260 and A280nm were measured on a Denovix DS-11 Fx to qualitatively illustrate A260/280nm and A260/230nm ratios as surrogate measures of DNA purity. A260/280 had to be 1.8 or greater and A260/230 had to be 2.0 or greater. Then, DNA was quantified using LifeTechnologies Qubit dsDNA BR kit (cat no Q32850) and we required a minimum of 50ul at 25ng/ul for WGS. Thirdly, DNA was diluted to 25ng/ul and a representative sample was loaded onto a 0.8% TAE gel, ran at 100v for 60mins and then imaged using a BioRad ChemiDoc imaging system to visualise the DNA quality.
HiSeq X Ten
Illumina NovaSeq 6000
68
EGAD00001010139
Somatic RNA for 37 samples was extracted using the Qiagen Qiasymphony RNA protcol (cat no 931636). The tissue was initially homogenised using a Qiagen Bioruptor, followed by the manufacturers recommended protocol (including DNase digestion). The resulting RNA the underwent quality control as follows: firstly, A260 and A280nm were measured on a Denovix DS-11 Fx to qualitatively illustrate A260/280nm and A260/230nm ratios as measures of RNA purity. A260/280 had to be 2.0 and A260/230 had to be 2.0-2.2. Then RNA was quantified using LifeTechnologies Qubit RNA BR kit (cat no Q10210). RNAseq was carried out by the Edinburgh Clinical Research Facility on an Illumina NExtSeq500. Total RNA samples were assessed on the Agilent Bioanalyser (Agilent Technologies, #G2939AA) with the RNA 6000 Nano Kit (#5067-1512) for quality and integrity of total RNA, and then quantified using the Qubit 2.0 Fluorometer (Thermo Fisher Scientific Inc, #Q32866) and the Qubit RNA HS assay kit (#Q32855). Libraries were prepared from total-RNA sample using the NEBNext Ultra 2 Directional RNA library prep kit for Illumina (#E7760S) with the NEBNext rRNA Depletion kit (#E6310) according to the provided protocol. 400ng of totalRNA was then added to the ribosomal RNA (rRNA) depletion reaction using the NEBNext rRNA depletion kit (Human/mouse/rat) (#E6310). This step uses specific probes that bind to the rRNA in order to cleave it. rRNA-depleted RNA was then DNase treated and purified using Agencourt RNAClean XP beads (Beckman Coulter Inc, #66514). RNA was then fragmented using random primers before undergoing first strand and second strand synthesis to create cDNA. cDNA was end repaired before ligation of sequencing adapters, and libraries were enriched by PCR using the NEBNext Multiplex oligos for Illumina set 1 and 2 (#E7500). Final libraries had an average peak size of 271bp. Libraries were quantified by fluorometry using the Qubit dsDNA HS assay and assessed for quality and fragment size using the Agilent Bioanalyser with the DNA HS Kit (#5067-4626). Sequencing was performed using the NextSeq 500/550 High-Output v2 (150 cycle) Kit (# FC- 404-2002) on the NextSeq 550 platform (Illumina Inc, #SY-415-1002). Libraries were combined in an equimolar pool based on the library quantification results and run across 5 High-Output Flow Cell v2.5.
NextSeq 550
37